Fabrication Everything From JBwelded/Fluxcored downpipes to Equal length SS Manifolds.

sealing up v bands

Old Mar 27, 2008 | 11:18 PM
  #31  
93hatchturbo's Avatar
Thread Starter
1.0 BAR
 
Joined: Jul 2003
Posts: 541
Default Re: sealing up v bands

Originally Posted by josh19wrc
buy a gasket to go in between them. They make them for this exact reason.
seriously?

I got the v band issue sorted but thats interesting if they actually have a gasket.
Old Mar 27, 2008 | 11:19 PM
  #32  
Smith-02's Avatar
0.0 BAR
 
Joined: Apr 2006
Posts: 0
Default Re: sealing up v bands

aluminum duct tape will work in a pinch. do it right and get a good bit of mileage out of it
Old Apr 2, 2008 | 06:43 PM
  #33  
alx954's Avatar
1.0 BAR
 
Joined: Jan 2005
Posts: 308
Default Re: sealing up v bands

I used bearing grease on mine, it turned into carbon then it sealed.
Old Apr 3, 2008 | 09:06 PM
  #34  
Eville140's Avatar
1.5 BAR
 
Joined: May 2005
Posts: 840
Default Re: sealing up v bands

I have been having a v-band that goes with a JGS 50mm gate kicking my *** for 2 days. I'm tigging it, down to low amps (like 45-50), crisscrossing, letting it cool, and clamping it to the gate so tight I'm afraid I'm going to snap the band. And there is no way to belt sand it as the wastegates valve seal has a notch that stick out that goes into a machined slot in the v-band. Real pita setup, but a big gate for the money


Old Apr 4, 2008 | 12:53 PM
  #35  
rsmith2786's Avatar
1.5 BAR
 
Joined: Aug 2003
Posts: 1,162
Default Re: sealing up v bands

They do make gaskets. You could also cut your own out of a sheet of gasket material.
Old Apr 26, 2008 | 03:54 AM
  #36  
Wideopentuning's Avatar
0.5 BAR
 
Joined: Apr 2006
Posts: 92
Default Re: sealing up v bands

If you let 1/4" of pipe stick out of one of the vband flanges so it can slide into the other flange before you put the clamp on it may eliminate any leaks even with a slightly warped flange.
Old Apr 27, 2008 | 02:32 AM
  #37  
turbob16hatch's Avatar
1.0 BAR
 
Joined: Dec 2005
Posts: 397
Default Re: sealing up v bands

Originally Posted by Eville140
I have been having a v-band that goes with a JGS 50mm gate kicking my *** for 2 days. I'm tigging it, down to low amps (like 45-50), crisscrossing, letting it cool, and clamping it to the gate so tight I'm afraid I'm going to snap the band. And there is no way to belt sand it as the wastegates valve seal has a notch that stick out that goes into a machined slot in the v-band. Real pita setup, but a big gate for the money
now idk if there flanges are different size, thickness or material then the ss tial v band flanges. but i have never had a sealing problem or warping problem when i weld them.

i set my amps at 85 and use 1/16th 308l rod. i just do 2 passes to get a big enough weld. i go around the whole thing then let it cool with a fan, then go back around it again. start to finish i have about 10-15 min in the weld.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
WTF
Forced Induction
10
Jun 21, 2007 08:13 AM
TechX
Forced Induction
9
Jun 6, 2005 03:25 PM
BlinD
Forced Induction
10
Jul 21, 2003 07:43 PM


Thread Tools
Search this Thread

All times are GMT -5. The time now is 03:20 AM.