Cant get turboedit to data log?
#1
Cant get turboedit to data log?
I Have a pm6 and a data loger that I installed the other day. I also Download TurboEdit Version 2.6.1 From chris. I cant figure out how to make it work, or the order to set up the dataloger features. If some one has a step by step that thay could point out, it would help out.
#4
Re: Cant get turboedit to data log?
Originally Posted by xenocron
I disagree...the version posted on my site is the only I can get to work.
You must be using NG60 code 1st! And your drivers must installed properly and your COM ports setup accordingly...
You must be using NG60 code 1st! And your drivers must installed properly and your COM ports setup accordingly...
#5
Re: Cant get turboedit to data log?
I tried the ng55 and I couldent get it to work, Chris said it had to be a ng60 so I burned a ng60 and I still couldnt ge tit to work. I want to smash this ---- all over the street. Its so ------- frustrating!!!!!
#6
Guest
Posts: n/a
Re: Cant get turboedit to data log?
Originally Posted by ratcityrex
I tried the ng55 and I couldent get it to work, Chris said it had to be a ng60 so I burned a ng60 and I still couldnt ge tit to work. I want to smash this ---- all over the street. Its so ------- frustrating!!!!!
#9
Re: Cant get turboedit to data log?
Only when it was in the wrong port. I can get it to conect, then I press start loging and the light on the usb conector starts blinking green, but nothing shows up on my screen. If I press the active dash everthing gos all fucked up. It says that im doing 65 mph and my water is like 165* and my intake temp is 165*, but im just at idle.
#10
Re: Cant get turboedit to data log?
TOOLS --> OPTIONS--> Communication
#1 - Set datalogging to the COM port assigned by your drivers (find this in the device manager, dont just try random COM ports)
#2 - Set real time programming to the proper COM port or something other than your datalogging port if not using Ostrich
#3 - Baud Rate 38400
APPLY AND CLOSE
FILE --> DATALOGGER
Connect
Start Logging
#1 - Set datalogging to the COM port assigned by your drivers (find this in the device manager, dont just try random COM ports)
#2 - Set real time programming to the proper COM port or something other than your datalogging port if not using Ostrich
#3 - Baud Rate 38400
APPLY AND CLOSE
FILE --> DATALOGGER
Connect
Start Logging