Forced Induction Custom FI Setup Questions

Internal to external Wastegate...

Thread Tools
 
Search this Thread
 
Old May 5, 2006 | 01:44 AM
  #1  
CRX_Si's Avatar
Thread Starter
1.0 BAR
 
Joined: Nov 2005
Posts: 204
Default Internal to external Wastegate...

I searched and cant seem to find the page where it was asked before....Now what it is i wanna know is, Can i remove the Internal wastegate and weld the gate shut, Buy a external Wastegate manifold with wastegate, and be just fine?
Old May 5, 2006 | 01:52 AM
  #2  
whiterice's Avatar
3.0 BAR
 
Joined: Jun 2003
Posts: 3,974
Default Re: Internal to external Wastegate...

what turbo?
Old May 5, 2006 | 01:59 AM
  #3  
CRX_Si's Avatar
Thread Starter
1.0 BAR
 
Joined: Nov 2005
Posts: 204
Default Re: Internal to external Wastegate...

oh my bad, its a 2 gen dsm t25...
Old May 5, 2006 | 02:10 AM
  #4  
whiterice's Avatar
3.0 BAR
 
Joined: Jun 2003
Posts: 3,974
Default Re: Internal to external Wastegate...

You could remove the wastegate flapper and fill the hole on the side. Run the ext. wg from the second hole on the t25 dp flange. might wanna port the lip on the turbine housing in this case.

You could leave the stock int. wg and just remove the vacuum source. Run an ext. wg on the mani.

You dont need to buy a new mani!
Old May 5, 2006 | 02:17 AM
  #5  
CRX_Si's Avatar
Thread Starter
1.0 BAR
 
Joined: Nov 2005
Posts: 204
Default Re: Internal to external Wastegate...

Originally Posted by whiterice
You could remove the wastegate flapper and fill the hole on the side. Run the ext. wg from the second hole on the t25 dp flange. might wanna port the lip on the turbine housing in this case.

You could leave the stock int. wg and just remove the vacuum source. Run an ext. wg on the mani.

You dont need to buy a new mani!
ok, so it can be done, now the way i said earlier, could that work to..Weld the flap completely shut, then just plug the Dump part for the wastegate on the dp flange..Then i could put an external up top on the manifold...
See cause i wanna remove the IW for good due to lack of room...
Old May 5, 2006 | 02:19 AM
  #6  
whiterice's Avatar
3.0 BAR
 
Joined: Jun 2003
Posts: 3,974
Default Re: Internal to external Wastegate...

right.
here is the first suggestion:

Old May 5, 2006 | 02:35 AM
  #7  
CRX_Si's Avatar
Thread Starter
1.0 BAR
 
Joined: Nov 2005
Posts: 204
Default Re: Internal to external Wastegate...

So in this pic here, i would leave the flapper open and just remove the vac source and wastegate..correct?
Old May 5, 2006 | 09:02 AM
  #8  
iamanonymous's Avatar
0.0 BAR
 
Joined: Apr 2005
Posts: 23
Default Re: Internal to external Wastegate...

Originally Posted by whiterice
omfg i want that bad for my 91 accord!!!!
Old May 5, 2006 | 09:48 PM
  #9  
con's Avatar
con
0.0 BAR
 
Joined: Nov 2003
Posts: 0
Default Re: Internal to external Wastegate...

Originally Posted by whiterice
----, you would get less boost creep with the stock gate then that
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Scott-EP
Wanted
1
Dec 22, 2006 01:59 PM
djay86
Forced Induction
10
Nov 26, 2005 03:56 PM
eg6hatch315
Forced Induction
1
Mar 22, 2005 09:51 PM
Turboman
Forced Induction
2
Jan 2, 2003 06:11 PM
fiero_god
Forced Induction
8
Dec 22, 2002 06:10 PM