Fabrication Everything From JBwelded/Fluxcored downpipes to Equal length SS Manifolds.

First collector attempt

Thread Tools
 
Search this Thread
 
Old 01-04-2008, 01:14 PM
  #21  
0.5 BAR
Thread Starter
 
vtec_lude's Avatar
 
Join Date: Jul 2007
Posts: 66
Default Re: First collector attempt

I've just got a few questions.

The first pass I get a nice shiny weld and looks pretty good. I wanted to make another pass but the welds turn out undefined and grey, almost like a mig weld.

The first pass I use 60amps with 10lpm gas flow. I haven't got a pedal so I pretty much do a few welds and wait for it to cool before I continue.

On the second Pass I find I need to use more heat so I bump it up to about 90amps with the gas flow on 15lpm.

This is all on sch10 316l stainless pipe.

Any advice would be much appreciated.

thanks
vtec_lude is offline  
Old 01-04-2008, 06:49 PM
  #22  
0.0 BAR
 
Smith-02's Avatar
 
Join Date: Apr 2006
Posts: 0
Default Re: First collector attempt

youre cleaning your ---- between passes right?

1 Lpm = 0.03532 cfm

10lpm = .3cfm..

stop being so stingy with argon and just crank that up to like.. 50lpm, unless the conversion is wrong.
Smith-02 is offline  
Old 01-04-2008, 09:10 PM
  #23  
0.5 BAR
Thread Starter
 
vtec_lude's Avatar
 
Join Date: Jul 2007
Posts: 66
Default Re: First collector attempt

Ok I'll bump it up and see what happens. Argon is really expensive over here in the UK... everything is...
vtec_lude is offline  
Old 01-04-2008, 10:38 PM
  #24  
3.0 BAR
 
Toysrme's Avatar
 
Join Date: May 2005
Posts: 1,811
Default Re: First collector attempt

10-20 CF/H (good general argon flow rate) =
4.7-9.4 liter/minute
Toysrme is offline  