Just get the same plug as your shop as long as its 230 single phase and make sure you check the breaker its on. The plug configuration is an indicator of the amp draw in most cases.
SpankedYA! is offline  
Old 02-12-2007, 07:29 PM
  #3  
3.0 BAR
 
Toysrme's Avatar
 
Join Date: May 2005
Posts: 1,811
Default Re: 230 single phase

220 is 220 is 220 in the US. 110v = a hot, a neutral & a ground.
220v = a 110v hot, another 110v hot & a ground.

All you gotta do is put a new plug on it. Just make sure it's rated for the correct amperage!



If you wanna blow $40, and you are completely unable to remove the welder's plug. (Which would be stupid!) You could buy the male plug to fit your current female (outlet). Wire it to a female plug meant for your current welder's plug. There's your quite expencive plug adapter.
Toysrme is offline  
Old 02-12-2007, 08:45 PM
  #5  
3.0 BAR
 
Toysrme's Avatar
 
Join Date: May 2005
Posts: 1,811
Default Re: 230 single phase

It's 20 amps.
Aslong as the wiring & outlets are also wired to handle atleast a 20amp load. You'll be OK.
Modern inverter welders ramp their current draw up in a way that you can normally exceed the amount a breaker, or a slow blow fuse is rated for. Older transformer welders. It can be abig crap shoot. You'll blow a working 20amp breaker drawing 25amps through it, where you may draw 27amps just fine on a better high end inverter tig machine on the same breaker.


Just hook your ground up & then hook the hots where ever. Then run the thing. If the walls catch on fire, or the outlet melts... The wiring & outlets are not wired to code. If the breaker trips, reset it & cut the current down a smidge. You'll be just fine!
Toysrme is offline  
Old 02-12-2007, 09:02 PM
  #6  
3.0 BAR
 
E-b0la's Avatar
 
Join Date: May 2006
Posts: 1,967
Default Re: 230 single phase

Honestly why the ---- do they make about 15 differnent ------- 220v plugs? Wiring 220v welders can be a bitch when the plugs don't match but the 220v is definatly worth having.
E-b0la is offline  
Old 02-12-2007, 09:08 PM
  #7  
3.0 BAR
 
Toysrme's Avatar
 
Join Date: May 2005
Posts: 1,811
Default Re: 230 single phase

LoL! Who knows. Make sure you always have the gold plug ones instead of the aluminum ones tho. They're 15amp.
Best I can tell you, is some plugs must be a locking 3 prong, or locking 4 prong type.

Then you have different types of plugs for the common amperage ratings. 15 20 30 & 40amps are all different plugs.




Unlike 110 they do have to be different because hey want to be very sure that you can't put a 220v plug in a 110v outlet!
And like, 15 & 20 amp plugs have a (how do I temr it?) vertical prong & a horizontal prong. While 10 amp 110v's have a pair of vetical prongs.


It's just saftey stuff.
Toysrme is offline  
Old 02-13-2007, 07:35 PM
  #9  
3.0 BAR
 
Toysrme's Avatar
 
Join Date: May 2005
Posts: 1,811
Default Re: 230 single phase

OK, but for the cost of the phonecall. Why don't you call the seller & ask if re-plugging the unit will affect the warranty.
Toysrme is offline  
Old 02-13-2007, 11:08 PM
  #10  
0.5 BAR
 
sharkytm's Avatar
 
Join Date: Sep 2006
Posts: 120
Default Re: 230 single phase

Originally Posted by burkej62
For 230 volts you would need a 4 wire setup , 2 phases , 1 netrual and your ground . Altho 20 amps may have beenenough for your air compressor I HIGHLY doubt it is enough for your welder. What are the requirments ? [look for tag on welder itself]
From Miller's site:
Input Power

* Requires 1-Phase Power
* 230 V, 21.7 A, 60 Hz

20A will be fine, just dont crank it all the way up. Check and make sure that your 20A breaker is using the correct Romex wire, should be 14/3. You DON'T need 4-wire for 20A 240v, unless things have changed recently.

Build a converter cable, and I'd use a 6L-20P/6L20R for the cable end, and for the receptacle. Those are locking (twist-lok) connectors, so it'll be hard to pull the cable out of the wall.