Turbo Parts For Sale Sell your Turbo Related Stuff here!

Manual boost controllers

Thread Tools
 
Search this Thread
 
Old Jan 13, 2007 | 02:03 PM
  #11  
A20A3T's Avatar
0.5 BAR
 
Joined: Dec 2005
Posts: 103
Default Re: Manual boost controllers

is it possible to use one of these and 'disable' the internal wastegate so i would be able to run my tial wastegate?
Old Jan 13, 2007 | 04:09 PM
  #13  
A20A3T's Avatar
0.5 BAR
 
Joined: Dec 2005
Posts: 103
Default Re: Manual boost controllers

Originally Posted by jagojon3
You would probably need to use a blockoff plate for your downpipe which blocks the internal wg hole.
a block off plate is next to impossible to find since im using a turbo off a skyline. i was thinking of just turning up the boost on the internal wastegate to something like 20PSI while i use my tial as the actual wastegate set at anything under 20PSI
Old Jan 13, 2007 | 04:24 PM
  #14  
ju-on's Avatar
1.0 BAR
 
Joined: Jul 2005
Posts: 545
Default Re: Manual boost controllers

Just don't hook up a vacuum line to the internal gate, and run the MBC off the external gate.
Old Jan 14, 2007 | 06:15 AM
  #15  
78NOVA's Avatar
3.0 BAR
 
Joined: Dec 2005
Posts: 2,299
Default Re: Manual boost controllers

Originally Posted by ju-on
Just don't hook up a vacuum line to the internal gate, and run the MBC off the external gate.
wouldnt he still get blow-by from the internal wastegate, even though it isnt connected via boost controller due to exhaust pressure buildup?? wouldnt it have to be welded shut to prevent boost leak/surge??
Old Jan 14, 2007 | 11:50 AM
  #16  
Dr.Boost's Avatar
3.0 BAR
 
Joined: Mar 2003
Posts: 21,468
Default Re: Manual boost controllers

Originally Posted by ju-on
Thanks for the responce, but I thnk I'm going to pass then. I adjust it enough that I'd probably get a little annoyed by it. But for someone who never touches it once it is set, looks like a good deal! Good luck with the sale.
Well one end is straight so no matter where the other end is after adjusting, it's still going to fit the same way. :1
__________________
Best Car Insurance | Auto Protection Today | FREE Trade-In Quote
Old Apr 11, 2007 | 07:11 AM
  #17  
Chris Harris's Avatar
Thread Starter
3.0 BAR
 
Joined: Jul 2003
Posts: 6,447
Default Re: Manual boost controllers

Originally Posted by 78NOVA
wouldnt he still get blow-by from the internal wastegate, even though it isnt connected via boost controller due to exhaust pressure buildup?? wouldnt it have to be welded shut to prevent boost leak/surge??
it would probably be a good idea to tack weld it shut yes
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Schister66
Forced Induction
14
Jan 17, 2006 08:30 AM
StanB
Forced Induction
11
Dec 17, 2005 06:41 PM
Grand
Forced Induction
5
Aug 9, 2005 03:09 PM
SmoothGS
Forced Induction
7
Jun 3, 2004 11:39 PM
iNetForce
Forced Induction
15
Jun 2, 2004 08:30 PM




All times are GMT -5. The time now is 05:36 PM.