Slo_crx1 02-06-2006 05:00 PM

Re: HMT Electricians (boost, raffi, ???)
 
Pennsylvania requires at least 2x6" walls for outside and structural support walls. Basicly if you have a wall inside the house as well that acts as some type of support, it also has to be 2x6" studs, and always 16" on center. Almost every house i've ever wired (and good old PA doesn't require an electrical license either ;) ) usually has all 2x6 walls for the garages. When i wire a house though, all garages are done 20 amp circuits with GFCI's in 12/2 wire. If welders or extras are being added, then i check the amperage rating of the welder and run a dedicated circuit just for that alone. Normally only need around a 40amp (10/2 wire) circuit for a 110v mig welder, arc welders i do as 50 amp(8/3 wire), and tig's usually at 60amps with at least 6/3 wire. The higher amperage receptacles i usually add a disconnect as well. I'm not sure what national codes are electrical wise, but i'm pretty sure they're right along with what PA requires as well.

d16forlife 02-06-2006 11:13 PM

Re: HMT Electricians (boost, raffi, ???)
 

Originally Posted by slo_crx1
Pennsylvania requires at least 2x6" walls for outside and structural support walls. Basicly if you have a wall inside the house as well that acts as some type of support, it also has to be 2x6" studs, and always 16" on center. Almost every house i've ever wired (and good old PA doesn't require an electrical license either ;) ) usually has all 2x6 walls for the garages. When i wire a house though, all garages are done 20 amp circuits with GFCI's in 12/2 wire. If welders or extras are being added, then i check the amperage rating of the welder and run a dedicated circuit just for that alone. Normally only need around a 40amp (10/2 wire) circuit for a 110v mig welder, arc welders i do as 50 amp(8/3 wire), and tig's usually at 60amps with at least 6/3 wire. The higher amperage receptacles i usually add a disconnect as well. I'm not sure what national codes are electrical wise, but i'm pretty sure they're right along with what PA requires as well.

Dude you need to go buy a code book.#10 is only good for 30 amps ,#8 is only good for 40,and #6 is good for 55.

MikeJ-2009 02-06-2006 11:18 PM

Re: HMT Electricians (boost, raffi, ???)
 
Battle of the electricians. This is great. :6

hatchbox90 02-07-2006 12:17 AM

Re: HMT Electricians (boost, raffi, ???)
 

Originally Posted by d16forlife
Dude you need to go buy a code book.#10 is only good for 30 amps ,#8 is only good for 40,and #6 is good for 55.

false statement, #8 is good for 50 ampres, (IE) range