Forced Induction Custom FI Setup Questions

Turbo in- Oil spewing from DP

Old Jun 30, 2004 | 04:40 PM
  #11  
tegunderpressure's Avatar
Thread Starter
0.5 BAR
 
Joined: Apr 2004
Posts: 199
Default Re:Turbo in- Oil spewing from DP

http://www.atpturbo.com/Merchant2/me...egory_Code=OIL

One of these? Will it work with my StealthMode feed line?
Old Jun 30, 2004 | 05:18 PM
  #12  
nonvtec's Avatar
3.0 BAR
 
Joined: Aug 2003
Posts: 1,950
Default Re:Turbo in- Oil spewing from DP

It looks to me like the oil isn't being allowed to drain back into the pan and is backing up into the turbo. Doesn't it look like that to anyone else? Gravity doesn't go sideways for oil returns.
Old Jun 30, 2004 | 05:26 PM
  #13  
tegunderpressure's Avatar
Thread Starter
0.5 BAR
 
Joined: Apr 2004
Posts: 199
Default Re:Turbo in- Oil spewing from DP

But it does have a downward bend in the line.
Old Jun 30, 2004 | 08:03 PM
  #14  
Speedracer32's Avatar
1.5 BAR
 
Joined: Dec 2002
Posts: 877
Default Re:Turbo in- Oil spewing from DP

Originally Posted by nonvtec
It looks to me like the oil isn't being allowed to drain back into the pan and is backing up into the turbo. Doesn't it look like that to anyone else? Gravity doesn't go sideways for oil returns.
that's what i saw
looks damn near horizontal
Old Jun 30, 2004 | 09:03 PM
  #15  
tegunderpressure's Avatar
Thread Starter
0.5 BAR
 
Joined: Apr 2004
Posts: 199
Default Re:Turbo in- Oil spewing from DP

The second pic was at an angle, I deleted it. The return drops a good inch and a half downards from the turbo to the pan.
Old Jul 1, 2004 | 10:24 AM
  #16  
tegunderpressure's Avatar
Thread Starter
0.5 BAR
 
Joined: Apr 2004
Posts: 199
Default Re:Turbo in- Oil spewing from DP

What would I need to replace in order to run a -3an line?
Old Jul 1, 2004 | 11:27 AM
  #17  
PureCRXtasy's Avatar
1.5 BAR
 
Joined: Dec 2002
Posts: 1,065
Default Re:Turbo in- Oil spewing from DP

Originally Posted by tegunderpressure
What would I need to replace in order to run a -3an line?
I thought the stealthmode kits already used a -3 AN feed line?
Old Jul 1, 2004 | 11:47 AM
  #18  
djfob's Avatar
3.0 BAR
 
Joined: Dec 2003
Posts: 3,089
Default Re:Turbo in- Oil spewing from DP

My Stealth kit came with a -4 line. All you need to run a -3 line is new an fittings. Off the block fitting you'll need a 1/8 npt to -3 and off the turbo whatever size it is to -3.
Old Jul 1, 2004 | 01:39 PM
  #19  
tegunderpressure's Avatar
Thread Starter
0.5 BAR
 
Joined: Apr 2004
Posts: 199
Default Re:Turbo in- Oil spewing from DP

Yeah, mine says it uses a -4an line. I thought you had to use bspt for honda blocks? Stealthmode says the 14b used a 7/16 for the inlet. So I would need a 7/16 npt to -3an and a 1/8 bspt to -3an right? Where can I find these online?
Old Jul 1, 2004 | 03:19 PM
  #20  
tegunderpressure's Avatar
Thread Starter
0.5 BAR
 
Joined: Apr 2004
Posts: 199
Default Re:Turbo in- Oil spewing from DP

See first post.

Thread Tools
Search this Thread

All times are GMT -5. The time now is 04:18 PM.