Engine Management eCtune , Crome , AFC , FMU , Zdyne , Hondata , EMS , TE , Uberdata Anything to control your fuel, spark needs!

do i have a setting wrong? freelog & o-meter / lc-1

Thread Tools
 
Search this Thread
 
Old 05-19-2007, 01:47 AM
  #1  
1.5 BAR
Thread Starter
 
SmellySOHC's Avatar
 
Join Date: Oct 2004
Posts: 1,263
Default do i have a setting wrong? freelog & o-meter / lc-1

in freelog my o2 readings are different then my o-meter?? both ouputs on the lc-1 are the same 0-5v... is there a setting in freelog?? or which should i believe??
SmellySOHC is offline  
Old 05-19-2007, 11:24 PM
  #2  
3.0 BAR
 
ichbinsobose's Avatar
 
Join Date: Oct 2005
Posts: 3,450
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

how different are they? they should be really close
I got mine to be almost dead on in boost and on throttle
ichbinsobose is offline  
Old 05-20-2007, 02:47 AM
  #3  
1.5 BAR
Thread Starter
 
SmellySOHC's Avatar
 
Join Date: Oct 2004
Posts: 1,263
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

its like 11.5 0-meter , 12.7- freelog. pretty bad..
SmellySOHC is offline  
Old 05-20-2007, 10:12 AM
  #4  
3.0 BAR
 
stenseltizm's Avatar
 
Join Date: Sep 2004
Posts: 1,588
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

Originally Posted by SmellySOHC
in freelog my o2 readings are different then my o-meter?? both ouputs on the lc-1 are the same 0-5v... is there a setting in freelog?? or which should i believe??
There are settings in freelog, they need to be set to the same as the outputs on your lc-1
Freelog->Tools->Settings
Under the formulas tab I have O2 convert set to Wideband TBL,
then under the Wideband tab I set the Voltage and matching AFR in the upper left-hand corner to whatever the outputs on the LC-1 are set to.
With these settings logworks and freelog were just about spot on.
stenseltizm is offline  
Old 05-20-2007, 03:10 PM
  #5  
1.5 BAR
Thread Starter
 
SmellySOHC's Avatar
 
Join Date: Oct 2004
Posts: 1,263
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

nice , i remember doing so, but i will double check that. thanks!
SmellySOHC is offline  
Old 05-20-2007, 08:47 PM
  #6  
1.5 BAR
Thread Starter
 
SmellySOHC's Avatar
 
Join Date: Oct 2004
Posts: 1,263
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

Originally Posted by stenseltizm
There are settings in freelog, they need to be set to the same as the outputs on your lc-1
Freelog->Tools->Settings
Under the formulas tab I have O2 convert set to Wideband TBL,
then under the Wideband tab I set the Voltage and matching AFR in the upper left-hand corner to whatever the outputs on the LC-1 are set to.
With these settings logworks and freelog were just about spot on.
ya i did so and now logworks doesnt open. some error.. ----
SmellySOHC is offline  
Old 05-20-2007, 08:55 PM
  #7  
3.0 BAR
 
stenseltizm's Avatar
 
Join Date: Sep 2004
Posts: 1,588
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

Originally Posted by SmellySOHC
ya i did so and now logworks doesnt open. some error.. ----
what version are you running? sometimes it does that when a wrong setting gets set. I did the same thing with vs. 1.0.78 (some random setting changed itself?), the only way I could fix it was to dl and install 1.0.87 Beta

This should fix it if you already have 87
http://forum.pgmfi.org/viewtopic.php?t=12820
stenseltizm is offline  
Old 05-20-2007, 10:27 PM
  #8  
3.0 BAR
 
ichbinsobose's Avatar
 
Join Date: Oct 2005
Posts: 3,450
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

haha tim good times
ichbinsobose is offline  
Old 05-20-2007, 11:27 PM
  #9  
3.0 BAR
 
stenseltizm's Avatar
 
Join Date: Sep 2004
Posts: 1,588
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

Originally Posted by ichbinsobose
haha tim good times
yup yup,

From now on I follow the advice of unzipping this type of software into it's own folder so when I ---- it up somehow with upgrades or something, I have another version to fall back on.
stenseltizm is offline  
Old 05-21-2007, 12:02 AM
  #10  
1.5 BAR
Thread Starter
 
SmellySOHC's Avatar
 
Join Date: Oct 2004
Posts: 1,263
Default Re: do i have a setting wrong? freelog & o-meter / lc-1

Originally Posted by stenseltizm
then under the Wideband tab I set the Voltage and matching AFR in the upper left-hand corner to whatever the outputs on the LC-1 are set to.
can u print screen this chart??

or is it just this:
SmellySOHC is offline  


Quick Reply: do i have a setting wrong? freelog & o-meter / lc-1