Forced Induction Custom FI Setup Questions

Wastegates

Thread Tools
 
Search this Thread
 
Old 12-20-2002, 09:05 AM
  #1  
0.0 BAR
Thread Starter
 
madramper's Avatar
 
Join Date: Dec 2002
Posts: 2
Default Wastegates

Can I not use a wastegate and regulate my boost with a blow off valve?
madramper is offline  
Old 12-20-2002, 11:25 AM
  #2  
0.5 BAR
 
TurboCIvic2000's Avatar
 
Join Date: Dec 2002
Posts: 177
Default Re:Wastegates

You can't because the BOV just releases the pressure in the charger piping when you let go of the gas so the turbo can spool up quicker. The wastegate is used on the turbo itself. In the wastegate there is a spring that the pressure inside the turbo pushes against and when it reaches its max psi the wastegate dumps the excess flow in to the downpipe so you don't over boost.
TurboCIvic2000 is offline  
Old 12-21-2002, 03:15 PM
  #4  
0.0 BAR
 
Tom Stark's Avatar
 
Join Date: Dec 2002
Posts: 1
Default Re:Wastegates

There is another problem with using a blow off valve to regulate boost. While you can do that, it would only control boost, and would not reduce the back pressure or turbine speed. No "good" way (that is also cheap) to get around a problem. You need to invest the money into a wastegate, OR you can control the boost with the throttle. (As boost gets high, back off). It works fine, just the chance of "malfunction" is a little high!
Tom
Tom Stark is offline  
Old 12-21-2002, 05:53 PM
  #5  
3.0 BAR
 
BLACKSI's Avatar
 
Join Date: Dec 2002
Posts: 2,101
Default Re:Wastegates

some early turbo setups in books ive read use that as a method of boost control its not a good idea.

Beau
BLACKSI is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Sniperpain
Forced Induction
4
05-26-2003 12:00 PM
turbohf
Forced Induction
0
05-08-2003 02:39 AM
WebGeek
Forced Induction
8
05-07-2003 12:07 AM
J-MAN
Forced Induction
2
04-17-2003 08:56 PM
flipsoft
Forced Induction
3
04-12-2003 08:57 PM



Quick Reply: Wastegates



All times are GMT -5. The time now is 12:40 AM.