Re: any electricians in the house?
Make sure your wire coming from the pole is thick enough to support the added amperage
|
Re: any electricians in the house?
Originally Posted by d16forlife
They dont make mini 220 volt breakers ::). Minis run off of the same leg and only allow you to run 2 circuits off of the same phase. You need 2 phases, Aand B, to get 220 which means minis wont work. Stop giving advice about something you know nothing about.
so this guy wants to add a welder circuit and another 20 amp circuit or two. the breaker will look like this 50 ] welder phase a 20] add. plugs Phase a 20] add. plugs Phase b 50 ] welder Phase b see there, the 50's are on ddifferent legs. if youd like me to take a picture to prove you wrong then i will :6 http://img387.imageshack.us/img387/3912/002ec9.jpg Im pretty sure i had to work a few thousand hours and pass a few tests to get this, so as far as giving information i know nothing about, get off googles nuts moron |
Re: any electricians in the house?
Originally Posted by hatchbox90
they DO make mini 220 volt breakers moron, im a ------ electrician and see this ---- daily. even if you cant find mini 220 breakers, you can buy mini 15/20 amp ones. either way it will free up some space in the panel
so this guy wants to add a welder circuit and another 20 amp circuit or two. the breaker will look like this 50 ] welder phase a 20] add. plugs Phase a 20] add. plugs Phase b 50 ] welder Phase b see there, the 50's are on ddifferent legs. if youd like me to take a picture to prove you wrong then i will :6 http://img387.imageshack.us/img387/3912/002ec9.jpg Im pretty sure i had to work a few thousand hours and pass a few tests to get this, so as far as giving information i know nothing about, get off googles nuts moron You mighty as well be working at Home Depot for all I care. And for your information, the circuit breaker you described is not a mini, you retard. It's a combonation twin. A mini breaker is two slim line breakes that connect, tandom, to one leg. But what do I expect from a guy that dingbats houses all day. ::) Guys like you are comical to watch at the wholsale house. You fuckers never know the trade name of what you're looking for....dipshit. |
Re: any electricians in the house?
Originally Posted by d16forlife
Hahahah, ------- resi. mother fucker, a few thousand hours hugh? And what an 80 question test? Around here you need at minimum 5k hours and have to get at least a 75 on a 150 question test to get your "Journeyman" liscence. I'll take a picture of mine tomorrow and post it up just for you.
You mighty as well be working at Home Depot for all I care. And for your information, the circuit breaker you described is not a mini, you retard. It's a combonation twin. A mini breaker is two slim line breakes that connect, tandom, to one leg. But what do I expect from a guy that dingbats houses all day. ::) Guys like you are comical to watch at the wholsale house. You fuckers never know the trade name of what you're looking for....dipshit. round here? where are you from? round here is about 120 questions. and 70. ---- im only 22 and have about 1500 of commecrial hours as well. not bad for 3 years in the trade |
Re: any electricians in the house?
Originally Posted by hatchbox90
i suggested mini breakers to make room in the panel douche bag. and excuse me for not stating a combo twin that connects tnadomly ::), i figure somebody with inteligence could figure that out with my sweet exaple i put together 8)
round here? where are you from? round here is about 120 questions. and 70. ---- im only 22 and have about 1500 of commecrial hours as well. not bad for 3 years in the trade |