Forced Induction Custom FI Setup Questions

No water lines needed for under 8PSI?

Thread Tools
 
Search this Thread
 
Old 05-28-2003, 01:25 PM
  #1  
1.0 BAR
Thread Starter
 
DOHCZCEF9's Avatar
 
Join Date: Mar 2003
Posts: 305
Default No water lines needed for under 8PSI?

Is it not true that when boosting under 8PSi or close to it coolant lines really aren't neccesary you just have to make sure to let the turbo spool down right ? I'm woundering cause I've heard this and the way I had to change the compressor postion the water line inlet and outlet are really in the way and I'll have to modify the stock ones , buy SS braided line and 90degree elbows and make my own ( which will cost big $$$$ for everything ) or just not use the water lines. Thanks for any help.
-Jason-
DOHCZCEF9 is offline  
Old 05-28-2003, 02:03 PM
  #2  
1.0 BAR
 
XDEep's Avatar
 
Join Date: May 2003
Posts: 468
Default Re:No water lines needed for under 8PSI?

i say if you can do it for cheap, why not it can only help. most dont. do you really need ss lines tho? id just use some $1/ft oil cooler/tranny lines, tap the throttle body lines and wrap em with heat shielding
XDEep is offline  
Old 05-28-2003, 02:06 PM
  #3  
0.0 BAR
 
J-SMITH69's Avatar
 
Join Date: Dec 2002
Posts: 0
Default Re:No water lines needed for under 8PSI?

the amount of boost or size of turbo doesn't matter. its still sitting right where you exhaust comes out. which is hot no matter how much boost you're running.

turbo don't NEED the water hooked up. but its to try and make them last longer...
J-SMITH69 is offline  
Old 05-28-2003, 02:19 PM
  #4  
3.0 BAR
 
projekteg's Avatar
 
Join Date: Apr 2003
Posts: 11,058
Default Re:No water lines needed for under 8PSI?

i will work without them, but they only take a second to hook up and preserve your oh so valuable turbo, so why not just hook them up??
projekteg is offline  
Old 05-28-2003, 02:33 PM
  #5  
1.0 BAR
Thread Starter
 
DOHCZCEF9's Avatar
 
Join Date: Mar 2003
Posts: 305
Default Re:No water lines needed for under 8PSI?

Because the way it sits now for the coolant inlet sits after I rotated the compressor I'd either have to take my time with a tourch and bend it being careful not to kink it in the process or get a -AN 90 degree elbow thats $40 bucks alone. I'll try the best I can to make it work but just needed a back up plan
DOHCZCEF9 is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
donnyavery
Turbo Parts For Sale
4
09-11-2011 08:31 AM
akurtzer57
Forced Induction
7
12-28-2009 12:51 AM
vani11aic3
Forced Induction
84
03-05-2006 11:06 PM
cmyrex
Forced Induction
2
08-27-2005 09:19 AM
rexsk8er
Forced Induction
12
07-14-2005 05:19 PM



Quick Reply: No water lines needed for under 8PSI?



All times are GMT -5. The time now is 05:06 AM.