Forced Induction Custom FI Setup Questions

fuel management

Thread Tools
 
Search this Thread
 
Old 03-06-2005, 09:46 PM
  #1  
0.0 BAR
Thread Starter
 
turboD16z6's Avatar
 
Join Date: Mar 2005
Posts: 8
Default fuel management

if i go with the stealthmode 450 correctinject injectors would i still need some kind of fuel managment?
turboD16z6 is offline  
Old 03-06-2005, 10:36 PM
  #2  
1.5 BAR
 
warric_k's Avatar
 
Join Date: Sep 2003
Posts: 708
Default Re: fuel management

yes. read the faq, it's a wealth of information.

think of it this way:
if you ran 450cc injectors with your stock computer, which expects to see 240cc injectors, this is what would happen.
idle, computer says "FIRE INJECTOR 1 FOR 2.33MILLISECONDS" because the ecu is tuned for a specific amount of fuel to reach a specific air fuel ratio.
well, instead of 2.33msec of 240cc, you're firing off 2.33msec of 450cc. now, do you think that that is a good idea?
warric_k is offline  