Xenocron USB Datalog Problems
Hey Guys,
I'm having trouble data logging with Xeno USB Datalogging cable, I am either getting "Bad Response" or "Cannot connect to ecu" Anyone have any ideas on how to sort this thing out? |
Re: Xenocron USB Datalog Problems
What program are you suing? Is J12 cut?
|
Re: Xenocron USB Datalog Problems
Also, make sure datalogging is enabled in your bin.
|
Re: Xenocron USB Datalog Problems
Ok J12 wasn't cut...my mistake so i just removed the resistor and i'm going to try it again. I'll keep you guys posted, it's Crome 1.4.9 Pro
|
Re: Xenocron USB Datalog Problems
ok with J12 removed i get "could not connect to the ECU"
|
Re: Xenocron USB Datalog Problems
I'm just fed up with this USB cable!
|
Re: Xenocron USB Datalog Problems
What program are you using?
$10 says the cable is fine. |
Re: Xenocron USB Datalog Problems
lol I pretty sure the cable is fine too it's just such a pain in the ass to get it to work.
Crome PRO Beta 1.4.9 |
Re: Xenocron USB Datalog Problems
And do you have datalogging enabled on your bin?
|
Re: Xenocron USB Datalog Problems
Yup.
|
Re: Xenocron USB Datalog Problems
Do you have the driver installed for it? Make sure all settings are correct. You also have to plug in the cable before you open up crome.
|
Re: Xenocron USB Datalog Problems
I got it to log but the values are delayed and also I can't see any highlighted cells signifying what my ecu is using to calculate fuel/timing, etc.
|
Re: Xenocron USB Datalog Problems
Go into the Advanced Tab under the driver and change the latency from 16 (default) to 1
|
Re: Xenocron USB Datalog Problems
Ok Freelog works fine but Crome isn't showing me any highlighted cells however it seems to be working but i'm just not getting the pink highlighted cell, there is a pink triangle on the 3D map screen that is moving.
|
Re: Xenocron USB Datalog Problems
I think I have 1.2.5, and I get a sidebar for datalogging which shows all the parameters. It either works or not.
Recheck to see that datalogging was added to the BIN, that the cable settings are correct, and that CROME is looking for the correct COM port. Sometimes your PC sets it as the wrong COM #, and Crome isn't smart enough to do the legwork finding it for you. |
Re: Xenocron USB Datalog Problems
I don't know what kind of connector you are using, but double check if he is on the good side!
|
Re: Xenocron USB Datalog Problems
yeah...so i bought the tuner kit from xenocron...getting the hang of it...great investment.
My prob--ecu was sent to chris and he soldered in the zif socket and burned a chip for me...ecu worked great. I started playing with the moates ostrich and crome (basic) and copied the chip that chris made so i had a good place to start from. I made a NA chip for obd1 ls (just added launch control, edited idle and such) and it works great. However, i got the hulog and plug it in and try opening Logworks 2 which came with the tuning package, and it says "no realtime detected" I have all the ports set up right and everything...just curious if there's something obvious i'm missing out on. :1 |
Re: Xenocron USB Datalog Problems
Logworks is the software for the wideband, either a lc-1 or lm-1, that was bundled with your package. You must have that wired up and calibrated before it starts to log anything. Should be a serial port that hooks to the lappy. Check pgmfi.org if you need help wiring it up, they have a great write up for the widebands. Only problem is finding a good ground source to get your afr readings in logworks and crome close to each other.
|
Re: Xenocron USB Datalog Problems
Make sure the drivers are correctly installed and you have it on the right com port
|
Re: Xenocron USB Datalog Problems
Originally Posted by zebvaj
Logworks is the software for the wideband, either a lc-1 or lm-1, that was bundled with your package. You must have that wired up and calibrated before it starts to log anything. Should be a serial port that hooks to the lappy. Check pgmfi.org if you need help wiring it up, they have a great write up for the widebands. Only problem is finding a good ground source to get your afr readings in logworks and crome close to each other.
|
All times are GMT -5. The time now is 09:33 AM. |